06/09/26 at 19:52:03
Most recent 50 posts
Welcome, Guest. Please
Login
or
Register
Forums
»
TORII MK III
‹
Previous topic
|
Next topic
›
Pages: 1
using 7dj8/pcc88's instead of 6922/6dj8's (Read 4752 times)
JD
Seasoned Member
Offline
Posts: 569
using 7dj8/pcc88's instead of 6922/6dj8's
05/29/12 at 14:16:36
I've read that the 7dj8's can be used in place with great results on other amps but haven't heard about them being used in the Zen Torii. If true the price point is unbeatable especially for telefunken's. Also curious if these 7dj8/pcc88 would also work in the CSP2+.
Back to top
IP Logged
Share:
Likes:
Lon
Seasoned Member
Offline
"Love without
guts is
worthless!"
Philip K. Dick
Posts: 28209
Munson Township, OH
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #1 -
05/29/12 at 14:19:02
There have indeed been positive reports of the use of this tube type in the Toriis in this forum. (Look at the thread about tubes for a touch of seduction for example).
Haven't tried them myself, not really a fan of 6DJ8/6922 in the Torii.
Back to top
HR-1,ZBIT,ZROCK3,SEWE300B,Dynagrid Jr;Rega RP3+all GrooveTracer mods;PSAudio:PST+DSD DAC Mk II,NPC,PowerBases,AC-12 pwr cbls, Reference spkrcbls;Mapleshade SamsonV3;VeraFi Audio cpts VooDoo:Cremona+Amati interconnects;Stack EQ; headphones:Sennheiser HD800S,ZMF Ori
IP Logged
Share:
Likes:
JD
Seasoned Member
Offline
Posts: 569
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #2 -
05/29/12 at 14:50:13
thanks Lon missed that.
Back to top
IP Logged
Share:
Likes:
Lon
Seasoned Member
Offline
"Love without
guts is
worthless!"
Philip K. Dick
Posts: 28209
Munson Township, OH
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #3 -
05/29/12 at 15:08:55
You're welcome! It's often hard to locate things on a website like this! But fun to look.
Back to top
HR-1,ZBIT,ZROCK3,SEWE300B,Dynagrid Jr;Rega RP3+all GrooveTracer mods;PSAudio:PST+DSD DAC Mk II,NPC,PowerBases,AC-12 pwr cbls, Reference spkrcbls;Mapleshade SamsonV3;VeraFi Audio cpts VooDoo:Cremona+Amati interconnects;Stack EQ; headphones:Sennheiser HD800S,ZMF Ori
IP Logged
Share:
Likes:
Lord Soth
Seasoned Member
Offline
I'm an American
BadAss!
Posts: 300
Washington, D.C.
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #4 -
05/29/12 at 16:04:48
Hi JD,
I have rolled various PCC88/7DJ8 tubes in my CSP2+.
They work flawlessly in either the input tube position or in the L/R driver positions.
I have tried PCC88 tubes made by Siemens, Valvo, Philips, Lorenz and Telefunken. They definitely work!
BTW, the Lorenz PCC88 (Stuttgart Germany) sounds the best of all.
It even sounds better than a Siemens CCa Grey Shields.
It has a wide soundstage and 3D dimensionality and bass which makes one "feel" as though you were listening to speakers instead of headphones.
Back to top
IP Logged
Share:
Likes:
JD
Seasoned Member
Offline
Posts: 569
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #5 -
11/11/12 at 04:05:32
My CSP2+ is coming next week and I have a variety of tubes to roll some old cccp nos 6n1p's variety of 6922 bugles to ediswan and 7dj8's and a couple of rectifier's as well. Will post my findings although it might take some time to evaluate...still on the hunt for those Lorenz
Back to top
IP Logged
Share:
Likes:
Lord Soth
Seasoned Member
Offline
I'm an American
BadAss!
Posts: 300
Washington, D.C.
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #6 -
11/11/12 at 09:47:59
You might be able to get the Lorenz PCC88 from the head-Fi audio forum. They have a buy and sell forum there.
After Schiit came up with a solid state amp to replace the 6N1P based Lyr tube amp, ex-Lyr owners have been selling off their Lorenz tubes.
Back to top
IP Logged
Share:
Likes:
JD
Seasoned Member
Offline
Posts: 569
Re: using 7dj8/pcc88's instead of 6922/6dj8's
Reply #7 -
01/29/13 at 15:05:12
Recently picked up a pair of cryo'd platinum grade nos mullard 6922 and they aren't gonna come out. They weren't cheap and took some time to break in but they are the best input's i've heard in the Torii.
If you get a chance and have the coin try em. Still have 7dj8's in the CSP2+, telefunken up front with the nationals in the back.
JD
Back to top
IP Logged
Share:
Likes:
Pages: 1
‹
Previous topic
|
Next topic
›
Forums
» Powered by
YaBB 2.2.2
!
YaBB
© 2000-2008. All Rights Reserved.
Heavily modified by Steve Deckert for DECWARE LLC