SE84UFO2.1 dual miliamperes dial display purpose? (Read 67 times)
Sxmthuan
Verified Member
**




Posts: 25
SE84UFO2.1 dual miliamperes dial display purpose?
Yesterday at 19:03:23
 
Hi all,
I'm wonder what the purpose of these display in miliampere?
I have one amp with needle point at 29 mA on both channel (in green zone 20 mA - 30 mA)
Other amp's needle point at 33mA (yellow zone 30 mA - 34 mA)

Both are figured as bridged monos, and volume seems balanced between L and R
Any user adjustment needed. Should I worry if needle point to red zone 34mA plus?
Thank you
Thuan
Back to top
 
 
  IP Logged
CAJames
Seasoned Member
****


"I've run every
red light on memory
lane."

Posts: 2761
Re: SE84UFO2.1 dual miliamperes dial display purpose?
Reply #1 - Yesterday at 19:48:41
 
Quote:
osted by: Sxmthuan      Posted on: Today at 11:03:23

I'm wonder what the purpose of these display in miliampere?

...Any user adjustment needed. Should I worry if needle point to red zone 34mA plus?


I think the purpose is largely aesthetic. But technically what they do is show the plate current, aka the bias, on the power tubes. That is useful in two ways: one is generally the needles will be perfectly still, but as you start to approach clipping they will start to dance, in time with the music.

Also, while the absolute number on the dial isn't very important, if you see it go down it probably means your tubes are getting old and you should consider replacing them. But my (some what limited) experience is sound quality starts to diminish before the meter reading changes. Steve suggests every 6 months or so to swap out your current tubes with new ones and compare the sound. If the old ones still sound good than continue to play them. If the new one are better than thank the old ones for their service and leave the new ones in the amp. That makes a bunch of sense to me.

There are really no user adjustments possible, besides switching tubes, but if you see the meters go to zero, or get maxed out that means you've got a problem.


Back to top
 
 

[FOOBAR2000 | Jay's CDT2 MRK3] -> Denafrips Terminator 2 + Gaia
Sumiko Pearwood -> Mapleknoll Athena -> Luxman SUT -> Mapletree Phono 3E
STR-1002 -> Woo WA22 -> 2x UFO25s, balanced monos
Omega SAM , Hifiman Arya, Audeze LCD-XC
  IP Logged
Sxmthuan
Verified Member
**




Posts: 25
Re: SE84UFO2.1 dual miliamperes dial display purpose?
Reply #2 - Yesterday at 21:10:37
 
Thank you,
Very logic explanation Smiley
Regards
Thuan